SIB-01AI-H Ex
Single-channel analogue signal repeater 0(4)…20 mA from explosion hazard area, "transparent" for two-way HART protocol communication
- Analog input
- Number of channels: 1
- Analog signal repeater 0(4)…20 mA from explosion hazard area, “transparent” for two-way HART protocol communication.
- Can be used for sensor power supply.
SIB-02AI-H Ex
Two-channel analogue signal repeater 0(4)…20 mA from explosion hazard area, “transparent” for two-way HART protocol communication
- Analog input
- Number of channels: 2
- Analog signal repeater 0(4)…20 mA from explosion hazard area, "transparent" for two-way HART protocol communication.
- Can be used for sensor power supply.
SIB-01AI-SH Ex
Analog signal splitter 0(4)…20 mA from explosion hazard area, "transparent" for two-way HART protocol communication
- Analog input
- Number of channels: 1
- Analog signal splitter 0(4)…20 mA from explosion hazard area, "transparent" for two-way HART protocol communication.
- Can be used for sensor power supply.
SIB-01TI Ex
Single-channel converter of resistance thermometer or thermocouple signal from explosion hazard area to analog signal 0(4)…20 mA
- Analog input
- Number of channels: 1
- Converter of resistance thermometer or thermocouple signal from explosion hazard area to analog signal 0(4)…20 mA.
- Software configurable type of input sensor and conversion range.
SIB-02TI Ex
Two-channel converter of resistance thermometer or thermocouple signal from explosion hazard area to analog signal 0(4)…20 mA
- Analog input
- Number of channels: 2
- Converter of resistance thermometer or thermocouple signal from explosion hazard area to analog signal 0(4)…20 mA.
- Software configurable type of input sensor and conversion range.
SIB-01AO-H Ex
Single-channel analogue signal repeater 0(4)…20 mA to hazardous area, “transparent” for two-way HART protocol communication
- Analog input
- Number of channels: 1
- Analog signal repeater 0(4)…20 mA to hazardous area, "transparent" for two-way HART protocol communication.
SIB-02NI Ex
Two-channel switching amplifier/converter for NAMUR sensor input or dry contact from explosion hazard area to 24 VDC discrete signal output
- Discrete input
- Number of channels: 2
- Switching amplifier/converter for NAMUR sensor input or dry contact from explosion hazard area to 24 VDC discrete signal output.
- Diagnostic function for integrity of sensor communication line. Switching frequency up to 5 kHz.
SIB-04NI Ex
Four-channel amplifier/converter for NAMUR sensor input or dry contact from explosion hazard area to 24 VDC discrete signal output
- Discrete input
- Number of channels: 1
- Converter of 24 VDC input discrete signal into control signal for solenoid, signaling device or other load in explosion hazard area. Diagnostic function for integrity of loaded communication line.
- Device subgroup according to explosion category of mixture for which it is intended - IIC.
SIB-01SO-C Ex
Converter of 24 VDC input discrete signal into control signal for solenoid, signaling device or other load in explosion hazard area. Subgroup IIC
- Number of channels: 1
- Diagnostic function for integrity of loaded communication line.
- Device subgroup according to explosion category of mixture for which it is intended - IIC.
SIB-01SO-B Ex
Converter of 24 VDC input discrete signal into control signal for solenoid, signaling device or other load in explosion hazard area. Subgroup IIB
- Number of channels: 1
- Diagnostic function for integrity of loaded communication line.
- Device subgroup according to explosion category of mixture for which it is intended - IIB.